User guide
5
rather the top down.
• Always use soapy water to lubricate
gaskets prior to joint assembly. Do
not use Petroleum based lubricants!
• Plastic venting systems shall not pass
through rated re separations.
ADDITIONAL INSTRUCTIONS FOR
TERMINATION
M&G Duravent's PP Flex terminations are
specically designed for use with high-
eciency appliances that are known to
produce high volumes of uid due to
condensation of moisture within ue gases.
DO NOT modify these terminations.
IMPORTANT: Unless the appliance is designed
to address ow of condensates from the
vent system, a drain must be incorporated
within the vent to allow condensates and
rainwater to escape. This drain must include
a trap to prevent combustion gases from
entering living spaces. Be sure to check
the appliance manufacturer's installation
instructions closely in regards to condensate
management.
INSTALLATION OF FLEX GASKET:
PP Flex pipe must always have gaskets
installed on both ends of any installation.
Gaskets are installed on the ex pipe, with the
gasket seating inside the ex pipe grooves
(Fig.1). Use soapy water to assist installation.
1. Cut PP ex pipe (knife, saw, etc) to
desired length. Special care should be taken
to ensure cut is square, and the edge is
deburred.
2. Place Flex Gasket over Flex pipe and install
in the rst whole groove nearest the end.
3. Open the locking tabs (x2) of the
appropriate ex tting to accept the ex pipe
(Fig.2)
4. Apply soapy water to the gasket, and push
pipe/gasket into appropriate ex tting,
seating pipe down until it bottoms out
(Fig.2).
PP flex PiPe
PP flex Gasket
flex aDaPteR
(click!)
flex to coRRect
lenGth, clean eDGe
install Gasket, use
soaPy wateR
inseRt into
aDaPteR
lock PiPe to
aDaPteR
Figure 2, Installing Gasket / Flex Adapter
Figure 1, Mounting the Gasket
Gasket in
fiRst
GRooVe