FasNSeal Product Catalog
Commercial Applications
1
1
2
2
3
3
4
4
A A
B B
C C
D D
M & G
THIRD ANGLE PROJECTION
SHEET 1 OF 1
DWG NO
DRAWN
W. YOUNG
9/2/2010
SIZE
C
QA
CHECKED
APPROVED
MFG
REV
CUSTOMER #
PARTS LIST
CUSTOMDESCRIPTIONPART NUMBERQTYITEM
FSA-AE83004513
1
W2-9008100165122
FSA-SWDW810014633
6 in. lengthW2-AVL8-CL1039563
4
W2-3608100080 115
W2-AVL8100255 10
6
W2-1808100050
57
W2-1208100020 28
8 in. lengthW2-AVL8-CL103956
1
9
W2-2408100065 610
10 in. lengthW2-AVL8-CL103956
111
W2-4508100135112
W2-0608100006 113
FSA-DWSW81001983
14
FSBS8300191315
FSCL93003661316
3X
2X
4X
2X
2X
Boilers are:
Aerco
BMK. 2.0 (3X)
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPROVED
NOTICE: THIS DOCUMENT CONTAINS
PROPRIETARY INFORMATION AND IT SHALL
NOT BE USED, REPRODUCED, OR ITS
CONTENTS DISCLOSED, IN WHOLE OR I N
PART, WITHOUT THE EXPRESS WRITTEN
CONSENT OF PROTECH SYSTEMS A DIVISION
OF M & G DURA-VENT COMPANY, INC.
NOTES:
1. ALL WORKMANSHIP MUST MEET
AND/OR EXCEED ALL JURISDICTIONAL
REQUIREMENTS.
2. INSTALL A WALL BRACKET EVERY
TWELVE (12) FEET OF VERTICAL RUN.
3. USE A NON-COMBUSTIBLE HANGER
EVERY SIX (6) FEET OF HORIZONTAL
RUN.
4. USE FIRE-RATED FIRESTOPS WHEN
PENETRATING FIRE-RATED WALLS
AND/OR CEILINGS.
5. REFER TO THE FASNSEAL
INSTALLATION INSTRUCTIONS FOR
ADDITIONAL REQUIREMENTS.
NOTE: Every effort has been made to
Assure the accuracy of this information.
Dura-Vent cannot guarantee
Accuracy and will not be held liable for
Errors or omissions.
28.00 54.00
26.00
137.50
27.50
22.00
22.00
182.50
60.73
56.74
18.75
33.11
1
3
4
2
5
16
5
5
7
6
2
5
16
5
10
6
2
13
16
2
16
5
16
7
6
14
15
2
10
6
2
10
16
6 14
15
8
16
9
2
16
10
7
6 16
16
8
11
12
7
6
16
Commercial projects may require custom parts and unique system
designs. DuraVent oers complete project assistance:
Engineering Services: Personalized system design services oer
comprehensive CAD submittal drawing and complete bills
of materials.
Custom Parts: If your project requires innovative solutions, contact
DuraVent for custom parts that meet your specic project needs.
FasNSeal W2: FasNSeal W2 is the ideal choice for commercial
applications where there is a need for low clearances
to combustibles.
Up to 24” Vent Diameters: Many commercial applications require
large diameter systems due to the units size and output. Large
diameters are available in single and double wall, featuring
FasNSeal’s triple lipped directional gaskets and built-in locking band
which provides a safe and convenient installation.
Clearances Chart
FasNSeal
Rated Operating
Temperatures
Enclosed Unenclosed
Horizontal Vertical Horizontal Vertical
3” - 4”
194°F \ 90°C
(Canada Only)
0" 0"
300°F / 149°C
Sides: 8”/203.2mm
Top: 12”/304.8mm
Bottom: 4”/101.6mm
4”
101.6mm
1” / 25.4mm
480°F / 249°C 3” / 76.2mm 1” / 25.4mm
5” - 24”
194°F / 90°C
(Canada Only)
0" 0"
300°F \ 149°C
Noncombustible Enclosure
3” / 76.2mm 3” / 76.2mm
480°F \ 249°C 3” / 76.2mm 3” / 76.2mm
FasNSeal W2
Rated Operating
Temperatures
Enclosed Unenclosed
Horizontal Vertical Horizontal Vertical
3” - 4”
194°F
(Canada Only)
0" 0" 0" 0"
300°F 3” 1” 1” 1”
400°F 6" 1” 3” 1”
480°F 6" 4” 3” 1”
5” - 16”
194°F
(Canada Only)
0" 0" 0" 0"
300°F 3” 1” 1” 1”
400°F 6" 1” 3” 1”
480°F 6" 6” 3” 3”
Rated Operating Temperature of 300°F = Max Flue Gas Temperature of 375°F
Rated Operating Temperature of 480°F = Max Flue Gas Temperature of 550°F
FasNSeal
| Special Gas Vent
DuraVent | www.duravent.com
235