DuraTech Feature Benet
Selkirk/Metalbestos UltraTemp
(Platinum)
ICC/Excel Olympia/Ventis Metalfab
SuperPro/Amerivent
Hart& Cooley
5" through 24" diameter selection
Gives the installer the largest variety of diameters to t and size the
replace or stove properly
5" to 24" diameters available. Only 5" through 8" diameters are available. 5'-12"diameters available 6" to 18" diameters available. 5” through 14” diameters available.
6", 9", 12", 18", 24", 36", 48" and 60" pipe lengths. Adjustable
pipe length also available for use between elbows.
Gives the installer the greatest variety of lengths to reach the desired
height with ease and least amount of pipe sections.
No 60" pipe lengths available longest length is 48". No 9", 36" or 60" pipe lengths available longest length is 48".
No 9" or 60" lengths. Fewer options and more trips up the
ladder for the installer.
No 9" or 60" pipe lengths. Fewer options and more trips up
the ladder for the installer.
No 9" or 60"pipe lengths available. Fewer combinations to
reached desired height and more trips up the ladder.
Twist Lock End Rings
Allows the installer to safely and easily connect and disconnect
chimney sections without mechanical fasteners. Encases insulation to
prevent exposure to outside elements. No locking bands required.
Locking bands required. Creating additional time and
complexity to the installation.
Screws needed requiring more installation time. No end ring
coverage exposing insulation to outside environment. 4 spot
welded connecting tabs creating weak connection between
inner and outer wall.
Screws needed requiring more installation time. Twist lock connection with exposed insulation.
Twist lock connection with required locking bands.
Increases installation time.
430 Stainless Steel Inner Wall
Corrosion resistant stainless steel with the smallest amount of
expansion when exposed to heat. Prevents hot spots from appearing
which could cause a re.
304 stainless steel inner. Expands almost twice as much
as 430 stainless steel. Could cause hot spots and gaps in
insulation.
304 stainless steel inner. Expands twice as much as 430 stainless
steel. Could cause hot spots and gaps in insulation.
Use either 304 or 316 inner wall with 430 SS outer wall.
300 series SS expands twice as much as 400 with less
memory causing stress on joints due to inconsistent
expansion.
Uses 430 Stainless Steel
304 Stainless steel inner wall expands twice as much as
430 which could cause hot spots.
.020" thick Stainless Steel Inner Wall
Thickest inner wall construction in the industry providing the best
protection from creosote res.
.016" Inner wall thickness .016" inner wall thickness. .016 inner wall thickness. .015" Inner Wall thickness .016" Inner Wall thickness
Option for either Stainless Steel or Galvalume Outer Wall
Customer has the option to use a less expensive galvalume outer for
interior chase installations to keep costs down.
Oers both Stainless Steel outer and Galvanized Steel outer.
Galvanized more likely to rust than galvalume.
Stainless Steel only option for outer casing adding cost. 430 SS outer wall is the only choice.
Oers both Stainless Steel outer and Galvanized Steel outer.
Galvanized more likely to rust than galvalume.
Only 304 Stainless Steel outer available. Makes inside
chase installations more expensive.
Light Weight Construction
The light weight Thermo Tech insulation makes pipe sections lighter
(5lbs per ft for 6" diameter) to allow the manufacture of 5' lengths. Thus
allowing the installer to make fewer trips up the ladder for a quick and
easy installation.
Packed chimney is a heavier product. 6lbs per foot for 6"
diameter.
4.2 lbs per foot for 6" diameter. No details supplied on insulation.
Chimney pipe is one inch wider in material making it more
heavy and awkward to handle.
Packed chimney is heavier product. 6lbs per foot for 6"
diameter.
1" Double Wall Insulated Pipe
Has the smallest outside diameter available to allow easy placement
between studs. i.e. 8" O.D. on 6" diameter pipe. Saves from having to
reframe around the chimney.
1" double wall insulated pipe construction. 1" double wall insulated pipe construction with no end caps.
1 1/4" double wall insulated pipe construction with no
end caps. O.D. on 6" pipe is 8.5" tighter t to framing.
1.5" double wall insulated pipe construction with opened end
caps exposing insulation to outside environment. They taut
1.5" clearance over others 2" clearance but with the added wall
thickness this chimney requires the same amount of spacing for
clearances as all others.
1" Double wall insulated chimney pipe.
1" Thermal Tech Blanket Insulation
Insures complete insulation coverage between inner and outer walls,
preventing any hot spots from appearing due to expansion of the
metal walls during operation. Hot spots could cause a re.
Solid pack insulation. Thermoplus insulation blanket. Exposed at the ends of the pipe. 1 1/4" insulation blanket. Exposed at the ends of the pipe.
1.5" Ceramic insulation blanket. Exposed at the ends of the
pipe.
1" Mineral Wool packed insulation.
Factory Installed Starter Section in the Support Box
Allows the installer a safe, quick and easy connection of chimney to
the support box.
Starter Section not installed in support box.
Flue extension is required to prevent pipe from passing through
support. Chimney is free oating in support box. A longer ue
extension is required for steeper sloped ceilings.
Universal Adapter must be placed on pipe before placing
into the support box. Adapter not attached to support
box.
Factory installed Starter Section in support box.
No Starter Section in supports. Pipe either rests in at
supports or passes through the support box where a
support clamp is required. More time to install. Pipe is not
secure in support when chimney sweep is cleaning up and
down with their brushes
DuraTech oers 3 support box heights. 12", 24" 36" along
with at and round supports.
Gives the installer the most options when dealing with ceiling slopes.
Creating the most aesthetically pleasing installation possible.
Only oers 24" height.
Square and Round Support boxes only oered in 24" height.
Square Support box not oered in 5". A separate support
extension is required for additional height.
11" and 24" are only heights available.
Oers only a short at ceiling support and a 29" pitched
ceiling support box.
One support box height of 17.5" is available. Field
fabrication and painting of extension necessary.
Reduced 10" wide Support Box for 6" diameter DuraTech
Allows for the smallest area of framing while still maintaining safe
and approved clearances to combustibles. Could prevent having to
reframe around chimney.
Only oers 14 1/4" width box. Oers a 10" wide square support for 6" diameter pipe. Only oers a 12"x 12" width box. Only oers a 12.5" wide support box. Only oers a 12" x 12" width box
Dura-Vent oers 3 easy options to attach Connector Pipe
to Chimney System with the DVL/DB adapter, the DB slip
connector or the snap lock adapter.
Allows the installer to connect either DVL, DuraBlack or snap lock
stovepipe to the support box or nishing collar for an easy and quick
installation. Adapter snaps into support box and allows for easy
disconnection and switching of connector pipe without disconnecting
chimney.
Supplies a nishing collar that must be screwed to chimney
pipe. Very dicult to switch out connector pipe.
Snap lock or UltraBlack double wall connector are screwed on to
the ue extension. The screws are covered up by the UltraBlack
trim collar. Dicult to disconnect and switch out connector pipe
at later date.
Oers Class A adapters that must be drilled and screwed
to connect Double wall black pipe to Class A. Also oers
a nishing band to cover up protruding Class A pipe at a
support box or wall pass-thru.
Stovepipe adapter must connect into the female end of a
pipe section. Must use painted sleeve to cover exposed Class
A pipe. No slip connection is available.
Stovepipe adapter must connect into the female end of a
pipe section. No slip connection is available.
15 and 30 Degree Elbows come with swivel base.
The swivel base allows the installer to line up the elbow without
having to unlock and reposition the elbow, saving time and money.
15 and 30 Degree Elbows come with swivel base. No swivel base. Requires screws to lock into place. No swivel base. Requires screws to lock into place. Elbows come with swivel base.
No swivel base. They have removed the locking
mechanism from the end caps to allow it to spin. Has to be
locked into place with locking bands. Adds time and labor.
15 and 30 Degree Elbows come in kits.
This insures that the installer gets both the oset and return elbow
along with an elbow support bracket to make a properly code
approved oset.
Oers elbow kits in 15°. Two 15° elbows combine to be
adjustable 0-30°. Locking bands required.
No kits you must buy elbows separately along with oset
support.
Oers 15 and 30 degree elbows in kits.
No kits available. Must buy elbows and elbow straps
separately.
Oers 15 and 30 degree elbows in kits.
Limited Lifetime Warranty
The best Warranty in the industry 15 years 100% coverage. 50%
thereafter giving the installer and home owner the greatest peace of
mind in a quality installation.
Limited Lifetime Warranty with 3 stage replacement 10
years 100%; 11-15 years 75% o; 15 years and over 50% o.
Limited Lifetime Warranty. 100% for rst 10 years except rain
caps 50% thereafter.
Warranty card must be registered with Olympia within
60 days of installation. Separate warranty requirements
for burning coal.
Limited Lifetime Warranty oered. 100% for rst 10 years;
50% thereafter. Warranty is not transferrable.
For products installed after January 15, 2007, Limited
Lifetime Warranty with 100% for rst 10 years; 75% for
11 to 15 years; 50% beyond 15 years. Warranty is not
transferrable
Adjustable Tee and Wall Support Brackets
Guarantees the proper clearance to combustibles while allowing the
installer to work around changing exterior wall surfaces avoiding any
eld fabrication or code violation.
Adjustable Tee support is oered. Wall support is also
adjustable.
Wall support provide vertical load bearing and lateral support.
They are adjustable horizontally away from the wall.
Wall support provide vertical load bearing and lateral
support. They are adjustable horizontally away from the
wall.
Tee support is adjustable. Wall strap requires an addition
wall band adjustment kit to make their wall support bracket
adjustable. More SKUs to order and bring to the jobsite.
Adjustable Tee support is oered.
Shroud Specications
Dura Tech's shroud specications allow the installer to create a UL listed
shroud to hide the termination at the top of the chase for the safest
possible installation.
Shroud specications available. No shroud specications available. No shroud specications available. Shroud specications are available. No shroud specications available.
Adjustable Height Attic Insulation Shield
Allows the installer to accommodate deep attic insulation without
having to eld fabricate an extension. Saves time and money.
Attic insulation shield is xed height of 11.5". Does not
adjust for deeper insulation in colder climates.
No separate attic insulation shield is oered. You use a radiation
shield which is adjustable and a separate storm collar to create
an attic insulation shield.
Extension piece has to be bought and stocked as a
separate sku.
Attic insulation shield is at a xed 18" height. The collar is not
removable because of required screen so extending the shield
by eld fabricating an extension is not possible in colder areas
where insulation is deeper.
Attic insulation shield xed at 12" height. Collar is
attached making it dicult to eld fabricate an extension
for deeper insulation in cold areas.
Removable Top Plate and Spark Arrestor on termination cap.
Allows for easy cleaning of chimney without having to disconnect and
remove the cap. Saving time and money in cleaning.
Termination cap has a locking band attachment requiring
removal of entire cap for cleaning.
Termination cap top plate is removable by 4 wing nuts for
cleaning.
Must remove whole cap for cleaning, Spark Arrestor has to be
purchased and stocked as a separate sku.
Must remove entire termination cap for cleaning.
Entire termination cap assembly must be removed to
clean chimney.