Instruction

16
4. Complete Installation: Refer to Steps 8,
and 9, in the Ceiling Supported Installation
section, to complete the Roof-Supported
installation.
TEE-SUPPORTED INSTALLATIONS
Tee-Supported installations are used when
passing through a wall to an outside chimney.
The required parts and general conguration
are as shown in Figures 23, and 24.
1. Place Appliance: Position the appliance
according to the manufacturer’s instructions.
2. Cut and Frame Opening: Cut
14-1/4 inch diameter holes in the inner and
outer walls. The center of these holes should
be aligned with the center of the stove’s ue
outlet collar. For new construction, prior to
sheetrock or other covering of the wall studs is
applied, frame a square opening between the
studs, as specied in Table 2. ( Figure 25).
Should it be necessary to go through concrete,
masonry, or cinder-block, a 14-1/4 inch
Figure 25
14 1/2”
14 1/2”
Figure 24
PIPE SECTION
6-INCH OR 9-INCH
SDP-P
WALL THIMBLE
SDP-WT
PIPE
SDP-P
TEE
SDP-T
TEE SUPPORT
SDP-TS
TEE CAP
(COMPONENT OF
SDP-T)
TEE CAP
COMPONENT OF
SDP-T
REMOVABLE
TRAY
(COMPONENT
OF SDP-TS)
5/16 X 3” LAG
SCREWS
(6 REQ) NOT
FURNISHED
Figure 23
WARNING:
VENTILATED
FLASHING MUST
BE USED WITH
ENCLOSURES.
ALLOW 1/2 INCH AIR
SPACE BETWEEN BASE
OF FLASHING OR COVER
AND ENCLOSURE
FRAMING.