Product Manual

A MAJOR CAUSE OF VENT
RELATED FIRES IS FAILURE
TO MAINTAIN REQUIRED
CLEARANCES (AIR
SPACES) TO COMBUSTIBLE
MATERIALS. IT IS OF THE
UTMOST IMPORTANCE THAT
DURABLACK BE INSTALLED
ONLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
NOTE:
Read through all of these instructions
before beginning your installation. Failure
to install as described in this instruction
will void the manufacturers warranty, and
may have an effect on your homeowners
insurance. Keep these instructions for
future reference.
NOT A UL LISTED PRODUCT
Dear Customer, Installer, or End User:
I welcome any comments regarding matters
pertaining to our Simpson Dura-Vent products.
I welcome any ideas, input or complaints and
I’ll make sure that someone responds directly
back to you.
Send your emails to:
president@duravent.com
If you are searching for tech support or product
information, please phone us at 800-835-4429.
Or email us at:
techsupport@duravent.com
Sincererly,
Steve Eberhard, President and CEO
Simpson Dura-Vent Co., Inc.
IMPORTANT
DuraBlack must be installed with at least an
18” Clearance to Combustibles.
Read all instructions carefully before starting
the installation. The Simpson Dura-Vent
warranty will be voided, and serious re,
health, or other safety hazards may result from
any of the following actions:
Installation of any damaged Dura-Black
component.
Unauthorized modication of any Dura-
Black component
Installation of any component part not
manufactured or approved by Simpson
Dura-Vent.
Installation other than as instructed by
Simpson Dura-Vent and the appliance
manufacturer. Consult your local building
codes before beginning the installation.
INSTALLATION PROCEDURE
Step 1. Insert the Slip Connector section
of pipe into the previously installed Ceiling
Support Box. Position it so the seams are
facing the wall, and the smooth side is facing
the room. Push it in rmly, until the locking
notches engage the top of the rim of the hole
in the support box. It is extremely important
that the Support Box be positioned so that
the single wall pipe is at least 18” from the
combustible wall, and also that the support
box protrudes at least 2” below the ceiling.
Reposition the Support Box if necessary, to
meet these two requirements.
Step 2. If you are installing the optional Trim
Collar, slide the Trim Collar upwards over the
Slip Connector, until it is next to the bead.
Using the two, pre-punched holes in the Trim
Collar as a guide, drill two 1/8” diameter holes
in the Support Box. Screw the Trim Collar to
the Support Box, using the two sheet metal
screws provided with the kit.