Installation Instructions
13
clockwise, place the left side, the
bottom side, and then the right side
around the opening in the siding. Refer
to Figure 12.
With the 4 pieces in place secure the
pieces together using the pre-drilled
holes and the screws provided.
Seal around the inside corners of the
Vinyl Siding Standoff to help ensure a
weather tight installation.
Attach the Horizontal Cap to the
Vinyl Siding Standoff. Line up the holes
in the cap with the holes in the Vinyl
Siding Standoff and secure with the (4)
long screws provided with the cap.
Secure the Vinyl Siding Standoff to
the wall as appropriate. Depending on
the construction of your wall, different
methods of securing the standoff and
cap may be required. The Vinyl Siding
Standoff’s anges extend 2” under the
siding and can be secured to the wall
by using screws through the siding
and ange if needed.
Seal around the perimeter of the
Vinyl Siding Standoff using non-
hardening waterproof sealant to help
ensure a weather tight seal.
The Counter Flashing is typically
installed before siding or stucco
is nished and helps to ensure a
weather tight penetration through
the wall. The Counter Flashing
allows stucco, or other materials,
to be nished up to the edges of
the Counter Flashing. Under no
circumstances should stucco or other
material cover Termination Cap or
air inlets. The Counter Flashing is
available in both 1-piece and 4-piece
versions.
Center the counter ashing on
the wall around the framed penetration.
Secure to the wall using the screws
provided or other necessary connector
depending on the wall material. Attach
the Horizontal Cap to the Counter
Flashing by lining up the holes in the
cap with the holes in the Counter
Flashing. Secure using the 4 long
screws provided with the cap (Fig. 12).
Attach the 4 pieces together
starting with the top piece and work
counter-clockwise.
Secure the 4 pieces together before
mounting Counter Flashing to the wall.
Mount the assembled Counter Flashing
on the wall, centered around the framed
wall penetration.
Depending on wall construction, use
screws or other suitable connector
through the anged edges to secure
Counter Flashing to the wall.
Seal around the perimeter of the
Counter Flashing using non-hardening
waterproof sealant to help ensure a
weather tight seal.
If the optional copper version of
Horizontal Termination Cap is installed,
use an appropriate non-combustible
material to avoid direct contact between
the galvanized and copper metals to
prevent possible galvanic reaction.