Installation
8
House Shield as shown in Figure 6. The
House Shield is used to protect the exterior
wall from vent discharge. Attach a Square or
Round Horizontal Cap. The Round Horizontal
Cap can be swiveled to be directed away
from nearby objects (fence, plants, etc.), but
must still be pointing in a generally downward
direction. Important: Horizontal Caps must be
pointed in a generally downward
direction to insure rain and snow do not enter
the cap, and cause potential damage to the
appliance. Either vent Cap should be at least
6” from the wall.
C. Follow the below listed NFPA 211 rule for
distance of exit terminal from windows and
openings:
NFPA 211 (2003 ed.) Section 10.4 Termination:
10.4.5 (1) The exit terminal of a mechanical
draft system other than a direct vent appliance
(sealed combustion system appliance) shall be
located in accordance with the following:
(a) Not less than 3 ft (.91m) above any forced
air inlet located within 10 ft. (3m).
6 INCHES
MINIMUM
ROUND
HORIZONTAL
CAP
(OPTIONAL)
OPTIONAL
HOUSE
SHIELD
SQUARE
HORIZONTAL
CAP
6 INCH
MINIMUM
BLACK INTERIOR
GALVANIZED EXTERIOR
(STAINLESS STEEL FOR
CORNVENT)
TEE SUPPORT
BRACKET /
WALL STRAP
DOUBLE
TEE WITH
CLEAN-OUT
ADAPTER
4 FT.
WARNING
Do not install any insulation or other
material inside the Wall Thimble.
Thimble to the wall with non-hardening
waterproof sealant. As an option, you may
also seal the gap between the pipe and Wall
Thimble with sealant.
If the ue exit is on back of the stove, and
a horizontal through-the-wall installation is
desired (Figure 6):
A. Place the appliance according to
manufacturer’s instructions.
B. Connect the Pipe Adapter to back of stove
and attach sufcient pipe to penetrate Wall
Thimble and extend at least 6” beyond the
exterior wall. You may install the optional