Installation

11
approval from the manufacturer of the stove
before drilling, tapping, or performing any other
alterations to the appliance.
 Connect the appliance to the coupling on
the bottom of the Flex Pipe, by twisting to the
locked position. Push the appliance into
the replace to its nal resting place. Go to the

RIGID
PELLET VENT
PELLET VENT
CAP
TALL CONE
FLASHING
SCREW STORM
COLLAR TO OUTER
LINER OF PIPE WITH
SHEET METAL
SCREWS. THIS WILL
SUPPORT SYSTEM.
FLEX PELLET
VENT
RIGID PELLET
VENT ATTACHED
TO THE STOVE
PELLET
STOVE
INSERT
TRANSITION TO
FLEX PELLET VENT


TEE SUPPORT
BRACKET
TEE WITH
CLEAN-OUT
FLEX PELLET
VENT
REAR EXIT
APPLIANCE
TOP EXIT
APPLIANCE
FLEX PELLET
VENT
PIPE
ADAPTER
B
C

6 INCHES
MINIMUM
MASONRY
ANCHORS
PELLET
VENT PIPE
NONHARDENING
SEALANT
PELLET VENT
CAP
TALL CONE
FLASHING
STORM
COLLAR

TALL CONE FLASHING
SHEET
METAL
SCREWS
TOP VIEW OF
STORM COLLAR
AND PIPE
SHEET METAL SCREW
(3 REQUIRED, DO NOT
PENETRATE INNER
LINER)
STORM COLLAR
VENT PIPE
top of the chimney and pull the vent system up
to it’s desired height.
For the termination of the pellet vent, you
will use a Tall Cone Flashing, and a Storm
Collar. This will require 14 inches of pipe above
the top of the masonry chimney. Pull the pipe
up through the ashing to the desired height.
Mark where the Storm Collar will go. Slip the
Storm Collar down over the pipe, and afx it to
the pipe with a 1/4”-long stainless steel sheet
metal screw. (Figures 13 & 14). The Storm
Collar will then support the entire vent system.
Install the Cap. Seal the joint at the Storm
Collar, and any other joints or seams which
may appear suspect. Figure 15 shows a Tall