Installation Guide

8
Chimney Adapter to the DVL/DuraBlack
Chimney Adapter.
E. Connect the appliance to the Chimney
Adapter using a Pipe Adapter, lengths of pipe
as required, and an Adjustable Length pipe.
Slide the Adjustable Length down over the
top pipe section, position the installation
vertically plumb, then slip the Adjustable
Length up and twist lock it to the Chimney
Adapter. Once all the components are rmly
seated and properly aligned, carefully drill
three 1/8” diameter holes through the outer
sleeve only in the center of the slots located
at the bottom of the Adjustable Length
pipe. Do not penetrate the inner liner. Use
(3) 3/8” length sheet metal screws to secure
the Adjustable Length pipe. The completed
installation will look like
Figure 7.
INSTALLATION INTO A MASONRY
FIREPLACE
1. Have the masonry chimney inspected by
a certied chimney sweep or installer, to
Figure 4
Figure 5
Figure 6
6 INCHES
MINIMUM
OPTIONAL
HOUSE
SHIELD
HORIZONTAL
CAP
6 INCH
MINIMUM
BLACK
INTERIOR
GALVANIZED EXTERIOR
TEE SUPPORT
BRACKET /
WALL STRAP
DOUBLE
TEE WITH
CLEANOUT
ADAPTER
4 FT.
adapter or connector going into the Ceiling
Support Box.
B. Visually inspect with a ashlight the
condition of the interior of the chimney
for cleanliness and structural integrity. All
evidence of soot and creosote must be
removed from the existing chimney system.
If you doubt your ability to accomplish this,
contact a certied chimney sweep. Do not
use chemical cleaners, as these can possibly
damage the inside of the chimney. Do
any required maintenance on the existing
chimney system at this time.
C. Install a DVL/DuraBlack Chimney Adapter
in the existing ceiling support box, as shown
in Figure 7. Note that the DVL/DuraBlack
Chimney Adapter only connects to DuraVent
chimney systems.
D. Connect and seal the appropriate size