Submittal

15
Figure 2
Figure 4
APPLIANCE
OUTLET
POLYPRO
VENT PIPE
TIGHTEN CLAMPS ON
RUBBER COUPLER
ADAPTER OR FERNCO
STYLE ADAPTER TO
SECURE VENT
PIPE TO APPLIANCE
JOINT CONNECTIONS
Locking Band (Old Design): Verify the gasket is seated
evenly inside the groove in the female end of the pipe.
For PP / Metal pipe with a locking tab, slide the Locking
Band on to the male pipe section Fig.2. Insert locking tab
into locking band recess, rotate button away from locking
band clasp, insert pipe sections, push lock band clasp
downward over the socket, disengage tab 1/4”-5/8” from
socket.
Locking Clamp (New Design): Verify the gasket is seated
evenly inside the groove in the female end. Assemble
the joint by passing the male end of the Polypro Pipe
through the Locking Clamp on the hose clamp side and
into the female end of the PolyPro pipe, (Fig.2a). Hook the
Locking Clamp onto the gasket extrusion on the female
end and tighten down on the hose clamp.
The new Locking Clamp design is backwards
compatible with pipe sections designed for use with
the Locking Band. Use pliers to break off the Locking Tab
with a twisting motion. Once removed, install the pipe
section following the Locking Clamp instructions. Locking
Clamps can be purchased separately in packs of 12.
Fig.2 and 2a. Screws are not allowed for joint
connection. Never penetrate the wall of PolyPro
Single-Wall vent pipe. (Exception: a stainless steel
screw may be used outside the building on exterior
termination fittings to orient an elbow, etc).
IMPORTANT: Locking Bands or Locking Clamps are
mandatory on all exhaust vent joints
POLYPRO TO DURAVENT / SECURITY CHIMNEY METAL
VENT CONNECTION
To transition from PolyPro to Duravent / Security metal vents
that are UL 1738 or ULC 636 listed, an approved adapter
must be used.
Installation of PolyPro (female) to metal vent adapter (male)
is the same process as illustrated in Fig.2 and 2a.
APPLIANCE CONNECTION: 2” - 4”
1. If the appliance has a PVC/CPVC female outlet use the
Appliance Adapter/ PVC Adapter and Clamp. (Fig.3)
If the appliance has a PVC/CPVC Male outlet use
a matching PVC/CPVC coupling to convert to a
female outlet.
2. If the appliance outlet has a rubber boot or Fernco-
style appliance adapter, then the PolyPro vent pipe
may attach directly to the appliance (Fig.4).
3. If the appliance has a FasNSeal outlet then use the
FasNSeal to PolyPro adapter.
Figure 3
POLYPRO PIPE
APPLIANCE
ADAPTER CLAMP
APPLIANCE ADAPTER/
PVC ADAPTER
APPLIANCE
EXHAUST OUTLET
OR PVC UNION
APPLIANCE
LOCKING
TAB
LOCKING
BAND RECESS
1/4"
CLICK!
LOCKING
BAND CLASP
VERIFY GASKET IS
SEATED IN FEMALE
END OF PIPE
NEW
LOCKING
CLAMP
TIGHTEN HOSE
CLAMP TO SECURE
JOINT
VERIFY LOCKING
CLAMP HOOKS
UNDER GASKET
EXTRUSION
Figure 2a