4.3.3 Set the mounting plate on the ceiling
brackets and ensure safe & fixing (use the bolts
attached to the ceiling brackets as Fig. Using the
ceiling brackets to hang from the ceiling, the
position of mounting plate can be adjusted in the
limit of 100 mm.
4.3.4 Do the same as step A to install the main
body.
DFor above ceiling:
4.4.1Fix the air curtain as in the procedure for
installing on the concrete wall.
4.4.2 The pipe as right Fig. Instructs.
5TECHNICAL PARAMETER
Max input
power
(W)
Max air
speed
(m/s)
Air volume
(m
3
/h)
Noise
(dB)
MODEL
Volt.
(V~)
Freq
(Hz)
H L H L H L H L
Net
weight
(Kg)
AAC-FM-1509SA1 380 300 2000 1600 67
65
13.5
AAC-FM-1510SA1 400 320 2300 1800 68
66
15.5
AAC-FM-1512SA1 530 450 2800 2200 69
67
17
AAC-FM-1515SA1
120 60
690 610
13 10
3600 2800 71
69