Specification Sheet
2 Form No. V1.0_02.21
Specifications are subject to change without notice.
© 2021 Ferguson Enterprises LLC
www.durastar.com
24,000 BTU/H FLOOR/CEILING HEAT PUMP SYSTEM
SYSTEM DATA
Refrigerant Type R-410A
Refrigerant Charge (oz.) 82.9
Oil Type Ester Oil VG74
Oil Charge (oz.) 22.7 (670 ml)
Design Pressure (PSIG) 550/340
LINE SET REQUIREMENTS
Connection Type Flare
Liquid Ø3/8" (Ø9.52mm)
Gas Ø5/8" (Ø16mm)
Pre-Charge Length 25'
Minimum Length 10'
Maximum Length 164'
Maximum Height Differential 82'
Additional Refrigerant (oz./ft) 0.32
SOUND PRESSURE (dB(A))
Indoor Unit
Low 42
Medium 48
High 53
Outdoor Unit
61
INDOOR UNIT DIMENSIONS
Unit Dimensions
Width 42 1/16"
Depth 9 1/4"
Height 26 9/16"
Carton Dimensions
Width 45 1/16"
Depth 12 1/2"
Height 29 3/4"
Net Weight
60.6 lbs.
Gross Weight
72.1 lbs.
OUTDOOR UNIT DIMENSIONS
Unit Dimensions
Width 37 1/4"
Depth 16 1/8"
Height 31 7/8"
Carton Dimensions
Width 42 15/16"
Depth 19 11/16"
Height 34 13/16"
Net Weight
141.1 lbs.
Gross Weight
152.1 lbs.
FAN DATA
Indoor Unit Air Flow (CFM)
Low 598
Medium 708
High 759
Moisture Removal (Pints/hr) 3.51
Drain Port O.D. / Drain Hose I.D. Ø1" (Ø25mm)