Installation Sheet - DRAS12F1B

DURASTAR.COM14
STEP 4: REMOVE FRONT PANEL AND FACE PLATE
To facilitate pipe and cable installation remove the front panel and face plate on the unit.
1. Slide the two tabs at the top of the front panel inward until they click.
2. Remove the four screws holding the face plate in place. Open at the bottom 30 and lift off the
face plate.
STEP 3: DRILL WALL HOLE FOR CONNECTIVE PIPING
1. Determine the location of the wall hole based on the location of the outdoor unit.
2. Using a 2 1/2" (65mm) core drill for units with a gas side connective pipe less than 5/8" (16mm),
or 3 1/2" (90mm) for units with a gas side pipe greater than or equal to 5/8" (16mm), drill a hole
in the wall. Make sure that the hole is drilled at a slight downward angle, so that the outdoor
end of the hole is lower than the indoor end by about 3/16 - 1/4" (5mm to 7mm). This will ensure
proper water drainage.
Wall
Indoor Outdoor
3/16-1/4”
(5-7 mm)
3. Place the protective wall hole sleeve (field supplied) into the hole. This protects pipes and
cables from sharp edges and will help seal the opening when you finish the installation process.
After the sleeve is inserted through the wall, connect the wall hole sleeve cover to the wall
sleeve on the outside end. Make sure the cover is flush with the outside wall.
3. Using a screwdriver, remove the string attached to the front panel. Gently let the front panel
fall forward and remove it.