Specifications
4. Power on Utilities
There are three power-on utilities to set up and test printer hardware. These
utilities are activated by pressing FEED button and by turning on the printer power
simultaneously. The utilities are listed as below:
1. Ribbon sensor calibration
2. Gap or black mark sensor calibration
3. Self-test
4. Printer initialization
4.1 Ribbon Sensor Calibration
Please follow the steps below to calibrate the ribbon sensor.
1. Turn off the power and wait 5 seconds.
2. Press and hold the FEED button then turn on printer power.
3. Release the button while the LED blinks red.
The LED color will blink in the following pattern:
Orange red (5 blinks) orange (5 blinks) green (5 blinks) solid green
4.2 Gap/Black Mark Calibration
Gap/black mark sensor sensitivity should be calibrated at the following
conditions:
1. The printer is brand new
2. The die-cut label stock has been changed
3. Printer initialization
Calibration of the gap or black mark sensor depends on the sensor setting in the
last print job. Please follow the steps below to calibrate the sensor.
1. Turn off the power and wait 5 seconds.
2. Press and hold the FEED button then turn on printer power.
3. Release the button while the LED blinks orange
The LED color will blink in the following pattern:
Orange red (5 blinks) orange (5 blinks) green (5 blinks) solid green
9