User`s guide
11. SYMPTOM: When using either small shrink tube or 1/2" vinyl, the print is
not aligned correctly or is constantly shifting out of place.
Possible Cause: Tape guide is either not loaded properly or not loaded at all.
Solution:
1. With the smooth side of the tape guide faced up, position the
uniquely shaped hole over that left spacer.
2. Push it down so the guide is locked in with the spacer.
3. Once in place, slide the spacers all the way together.
4. Run the supply underneath guide and through divot on the
underside.
12. SYMPTOM: The print is not aligned correctly or is constantly shifting.
Possible Cause: Adjustable label guides are not properly securing label stock.
Solution: Open top cover and move the guides towards each other to secure
edges of label stock.
13. SYMPTOM: Print quality is poor.
a. Possible Cause: Cover not closed properly.
Solution: Close top cover completely and make sure the right side and left
side levers are latched to top cover properly.
b. Possible Cause: Print darkness is set too high or too low.
Solution: Adjust the print darkness.
(See page 27 of User's Guide)
1. Open the Printers and Faxes folder.
2. Right-click on the Graphic Products DuraLabel
®
LabPRO and select
"Printing Preferences."
3. Click the Option tab.
4. Clicking the arrow next to the Print Speed box.
c. Possible Cause: Print speed is set too high or too low.
Solution: Adjust the print speed.
(See page 27 of User's Guide)
1. Open the Printers and Faxes folder.
2. Right-click on the Graphic Products DuraLabel
®
LabPRO and select
"Printing Preferences."
3. Click the Option tab.
4. Clicking and dragging the slider right or left.
-58-