A. Gap Mode
24
Press the or to move the cursor to the media type and press
to enter the sensor calibration mode.
Note: If printing from enclosed software/driver, the software/driver will send out
the GAP or BLINE command, which will overwrite the sensor type setting
set from the front panel.
A-1 Automatic
When you enter the [Automatic] option, you will see following message, and
the printer will feed 2 to 3 gap labels to calibrate the sensor sensitivity
automatically. When calibration is completed, the LCD screen will return to
the previous menu.
A-2 Manual
If “Automatic” sensor calibration is unable to adjust the supply, please use
“Manual” function to calibrate the gap sensor manually.
When you enter the [Manual] option, you will see following message. Please
complete these steps:
Paper Len.
00812 dot
1. Press to move the cursor
from left digit to right digit, and press
to set the value from “0” to “9”
and the “dot/ mm/ inch”. Press
to set the paper length into
the printer.
Calibration 1/4
> Gap Mode
Bline Mode
Cont. Mode
Gap Mode 1/4
> Automatic
Manual
Pre-Printed
Gap Mode
Automatic
Gap Mode 2/4
Automatic
> Manual
Pre-Printed