Owner Manual

1. Stop! Read all safety information rst.
2. Turn heater regulator knob counterclockwise to (OFF) [ ] position.
WARNING: Stand to the side of unit while lighting. Do not stand or have any part of your body
over or near the heater while lighting.
3. Slowly open cylinder valve by turning counterclockwise .
4. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas,
STOP! Follow the safety information on the tag attached to the heater. If you do not smell gas, go to
the next step.
5. Turn heater regulator knob clockwise to (LOW) [ ] position. Press in safety shut-off valve plunger.
(Fig. 3)
6. With safety shut-off valve plunger pressed in, immediately push down and release piezo ignitor button
repeatedly. This will light the burner. Mesh screen on burner glows red when lit.
7. Once the burner is lit, continue to depress the valve plunger for 30 seconds and then release.
Be careful not to shake the heater when releasing the plunger.
8. If burner does not light within 10 seconds, turn regulator knob to the (OFF) [ ] position. Wait at least
ve(5) minutes for gas to dissipate before relighting. If burner goes out, repeat steps 5 through 7 or use a
match. If heater will not light after repeated attempts do not attempt to repair heater. Return heater to near
est authorized service center or to the address on the back of this manual, freight prepaid.
9. When burner is lit, turn heater regulator knob to desired heat setting (LOW) [ ], (MED) [ ], or (HIGH) [ ].
LIGHTING INSTRUCTIONS FOR PIEZO IGNITION MODELS (CONTINUED)
TURNING OFF THE HEATER
1. Tightly close propane tank valve by fully turning clockwise .
2. Turn the heater regulator knob to the (OFF) [ ] position. Wait at least 30 minutes for the heater to cool
before handling heater.
3. Always remove the heater from the propane tank after each use and store indoors. Do not store heater while
attached to propane tank. Do not store propane cylinders in a building, garage or any other enclosed area.
VENTILATION
Always be sure to supply proper ventilation while operating this heater.
Provide a minimum of 1.5 square feet (0.14m
2
) opening for fresh air supply.
13
PROPANE TANK TOP HEATER
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!