Instructions / Assembly

PRODUCT SPECIFICATION
Voltage Frequency Wattage(Max) Max. Amperage
240 V~ 60 Hz 4800 W 20 A
E-4
Note: Tolerances on all specication: +5%, -10%
The heater, which has a thermal cut-off protection, is intended for garage or workshop.
If the thermal cut-off protection trips, switch off the power and unplug the cord from
the outlet. The unit should reset automatically after 10 minutes. If the thermal cut-off
protection trips again, determine the reason for overheating.
INSTALLATION INSTRUCTIONS
1. Read all IMPORTANT INSTRUCTION before installation this heater.
2. Keep the unit at least 10” (25.4 cm) away from any adjacent surfaces. This
minimum distance must be maintained.
3. Set the Thermostat dial to its counter-clockwise position.
4. Plug the heater into the properly grounded outlet only and make sure the cord is
fully inserted into the outlet.
240 AC 60Hz L
240 AC 60Hz N
GND
M
Figure B
Heater
Motor (Fan)
Constant
Temperature Switch
Thermostat