Instructions / Assembly

PRODUCT SPECIFICATION
Voltage Frequency Wattage Amperage
240V~ 60 Hz 5000W 20.8 A
E-5
Note: Tolerances on all specication: +5%, -10%
THIS UNIT OPERATES ON 240 VOLTS AC. IMPROPER INSTALLATION OR
FAILURE TO FOLLOW THE PROCEDURES AS OUTLINED IN THIS MANUAL CAN
RESULT IN SERIOUS ELECTRICAL SHOCK. DISCONNECT ALL POWER FROM
THE HEATER AT THE MAIN SERVICE BOX BEFORE ATTEMPTING TO INSTALL OR
SERVICE THIS UNIT.
WARNING
!
ALL ELECTRICAL WIRING MUST CONFORM TO LOCAL ELECTRICAL CODES.
HEATER CIRCUIT MUST BE PROTECTED WITH PROPER FUSES. SEE TABLE 1
ON PAGE 9.
WARNING
!
Proper size fuses and circuit breakers in accordance with the national electrical Code.
Note:For certain applications, conduit may be required . Check local electrical codes.
See Tabel 1, page 9.
if you run the wiring in conduit and wish to be able to turn the heater, be sure to
purchase enough exible conduit to allow the heater to be turned.
Connectors, cable,and hardware used to wire theHeater