Instructions / Assembly

WARNING
E-3
Model # DFH-107-T
!
Read Carefully- These instructions are written to help you prevent difculties
that might arise during installation of heaters. Studying the instructions rst may
save you considerable time and money later. Observe the following procedures,
and cut your installation time to a minimum. TO REDUCE RISK OF FIRE OR
ELECTRIC SHOCK;
1. Use minimum 75°C copper wire No.12 AWG only.
2. Heater air ow must be directed parallel to, or away from, adjacent walls.
3. Observe wall, oor, and ceiling clearance requirements.
4. All wiring must conform to national and local electrical codes and the heater
must be grounded as a precaution against possible electrical shock. Heater
circuit must be protected with proper fuse. See Table 1 on page 9.
5. The mounting structure and the anchoring hardware must be capable of
reliable supporting the weight of the heater and, if used, the mounting bracket.
6
.
All electrical power must be disconnected at the main service box before
installing, inspecting, cleaning or servicing the heater. This is a precaution to
prevent serious electrical shock.
7. Use for Double phase electric power only.