IV. CLEARANCES (Vent-free operation only)
Figure 2
Minimum Dimensions of Firebox
WARNING: Maintain or exceed the minimum clearances.
V. INSTALLING DAMPER STOP (Vented operation)
For vented operation of this appliance, a damper stop must be installed in the replace to prevent
full closure of the damper blade. The damper stop must be adjusted to provide a minimum ue
opening of 29 square inches. You can obtain a damper stop at your local hearth products dealer
or hardware store.
WARNING: The replace and log set function as a system. If the replace is spilling
combustion gases into the room (check draft with a match, candle or smoke stick), reposition
the damper clamp to open the damper wider, until a positive draft (i.e. all combustion
emissions go up the chimney) is obtained.
VI. INSTALLATION
1. Carefully remove the contents of the carton. You should nd:
• The burner / base (Figure 1)
• Six (6) separate ceramic ber articial logs (Figure 3). The actual number of logs is more but
the rear log is composed of more than one log that are all attached together.
• Two (2) appliance base screws inside a small bag.
• One AA battery.
If components are missing, contact Duraame Consumer Affairs.
2. Remove all these components from their packaging. When handling the logs, take care not
to damage them. Keep packing materials away from children, as they could be a choking or
suffocation hazard.
3. Check each component for shipping damage. If components are damaged, contact the store
where purchased or Duraame, Inc.
4. Check the rebox dimensions to ensure that they are at least equal to the minimum dimensions
Firebox Back
Firebox
Side
22”
18”
32”
15”