General Information
Limitations
This ooring has a Solid Polymeric Core (SPC) and is
designed to be installed indoors only as a “oating oor” for
residential applications. The optimal operating temperature
is between 40°F to 90°F (4°C to 32°C). Avoid prolonged
exposure to direct sunlight or other heat sources where
temperatures will exceed 90°F (32°C), as damage may
occur. This product is not suitable for heavy rolling loads.
Rolling chairs with soft or W-type casters and a maximum
rolling weight of 250 lbs. are acceptable, provided that a
polycarbonate chair mat is used to protect the ooring in
rolling chair areas. Do not secure ooring or furniture to
the suboor with mechanical fasteners or adhesives. Do
not install cabinets, kitchen islands, or other non-movable
furniture on top of this oor covering. If required or
concerned, immediately contact the technical department
at customercare@duradecor.com or 1 - (855) 700 - 5666 for
assistance. Copies of ASTM documents are available for
purchase at www.astm.org.
Warning
All local, state, and federal regulations must be followed;
this includes the removal of in-place asbestos (oor
covering and adhesive) and any lead-containing material.
The Occupational Safety and Health Administration (OSHA)
has exposure limits for people exposed to respirable
crystalline silica; this requirement must be followed. Do
not use solventorcitrus-based adhesive removers. When
appropriate, follow the Resilient Floor Covering Institute’s
(RFCI) Recommended Work Practice for Removal of Existing
Floor Covering and Adhesive. Always wear safety glasses
and use respiratory protection or other safeguards to avoid
inhaling any dust. The label, installation, and maintenance
instructions along with the technical data sheet, limited
warranty and anyappropriateSafety Data Sheet (SDS) of
all products must be read, understood, and followed before
installation commences. If the substrate or suboor fails
for any reason, then the oor covering limited warranty is
void.
Site Conditions & Storage
The prepared installation area must be fully enclosed and
weather tight. During the installation, any direct sunlight
should be blocked using blinds, drapes or other protection.
The ambient temperature during installation must be >
60°F (16°C), with a recommended maximum of 80°F (27°C).
Note: When installing at temperatures > 80°F (27°C),
the size of an expansion gap will increase when the oor
covering is cooled.
Documentation
Record and le the measured and observed site
conditions and test results, including all photographs and
corrective measures. Maintaining this documentation,
along with the original invoice and any labor receipts
throughout the warranty period, is recommended, as this
will be required in the unlikely event of a claim.