Installation of Integral Flanged Windows in Recessed Openings 
After Water-Resistive Barrier (WRB) Is Installed
B-9  Secure Upper Flap
A.  Flip down upper flap of DuPont
™
 Tyvek
®
 WRB so it lays flat across head flashing.
B.  Cut ~1" strip of the DuPont
™
 Tyvek
®
 WRB at lower horizontal edge of head flap.
C.  Continuous tape seams as shown with DuPont
™
 Flashing Tape. Skip-taping at head 
is acceptable if an air barrier is not required or if additional drainage is desired.
D.  Install mechanical fasteners through the flashing at the head flap.
A
D
C
B-10 Seal Interior Opening 
Install DuPont
™
 Residential Sealant or recommended sealant (and backer rod as 
necessary) around the window opening at the interior. It is also acceptable to use 
DuPont
™
 Window & Door Foam or recommended foam at the interior cavity of the 
jambs and head. If foam is used at the sill, recommended sealant should be used at the 
sill area behind the foam to ensure a proper water seal. The seal created by the sealant 
(and backer rod as necessary) will also serve as a back dam. DuPont
™
 Residential 
Sealant should be tooled flat to allow the natural curing process to create a concave 
shape. Be sure that the sealant penetrates the grooves of the DuPont
™
 FlexWrap
™
 N F.
Interior