Installation Guide

INCORRECT
DuPont
FlexWrap
reverse flashed
INCORRECT
DuPont
StraightFlash
flush with DuPont
FlexWrap
CORRECT
DuPont
StraightFlash
overlaps DuPont
FlexWrap
8
Copyright ©2008 E. I. du Pont de Nemours and Company. All Rights Reserved. v.2
STEP 8
A. Install door according to manufacturer’s instructions.
B. (Optional)–see General Instructions. Adhere high pressure skirt to the bottom threshold of the door.
C. Cut two pieces of DuPont
StraightFlash
or DuPont
FlexWrap
for jamb flashing extending 1” above door head
flange and below bottom edge of sill flashing. Remove release paper and press tightly along sides of door frame.
D. Cut a piece of DuPont
StraightFlash
or DuPont
FlexWrap
for head flashing, which extends beyond outer edges of
jamb flashings. Remove release paper and install completely covering mounting flange and adhering to exposed
sheathing or framing members (see D).
DuPont
Flashing Systems Installation Guidelines
NOTE: Do not reverse shingle. DuPont
StraightFlash
must overlap DuPont
FlexWrap
and adhere
to the substrate.