DuPont Recommended Low Expansion Foams*
MANUFACTURER PRODUCT NAME
Selena Tytan
™
Window & Door Pro
Todol E-Z Flo
* Apply per manufacturers’ guidelines. DuPont assumes no liability in use of recommended products; installers need to evaluate suitability
of recommended products in their end-use applications.
DuPont Recommended Fasteners*
MANUFACTURER PRODUCT NAME
DuPont DuPont
™
Tyvek
®
Wrap Cap nails
DuPont DuPont
™
Tyvek
®
Wrap Cap screws
DuPont DuPont
™
Tyvek
®
Wrap Cap staples (for Stinger
™
)
Several 1.0 inch minimum crown staples**
* Apply per manufacturers’ guidelines. DuPont assumes no liability in use of recommended products; installers need to evaluate suitability
of recommended products in their end-use applications.
** Except when installing DuPont
™
Tyvek
®
WRBs over foam sheathing.
General Instructions
DuPont
™
Flashing Systems products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to
remove moisture, dirt, grease and other debris that could interfere with adhesion.
ApplypressurealongentiresurfaceforagoodbondusingaJ-rollerorrmhandpressure.
Remove all wrinkles and bubbles by smoothing surface and repositioning as necessary.
When flashing the sill area for windows and doors, DuPont recommends the use of 7” wide DuPont
™
FlexWrap
™
for
2”x 4” framing and 9” wide DuPont
™
Flexwrap
™
for 2” x 6” framing. When rigid back dams are required or desired, an
option would be to use a ¾” corner guard (back dam) cut to the length of the sill and nail into place on the interior edge of
the sill prior to installation of DuPont
™
FlexWrap
™
. Then install DuPont
™
FlexWrap
™
over sill and corner guard back dam.
Door and window rough sill framing must be level or slightly sloped to the exterior to ensure proper drainage to the
exterior. DuPont recommends the use of the SureSill
™
Sloped Sill Pan
™
, manufactured by SureSill, Ltd, on all exterior doors
and in certain applications on windows. This best practice ensures continuous support with positive slope to the exterior.
Please contact your local DuPont
™
Tyvek
™
Specialist for additional information and installation instructions.
DO NOT STRETCH DuPont
™
FlexWrap
™
when installing along sills or jambs. DuPont
™
FlexWrap
™
is only intended to be
stretched when covering corners or curved sections.
DuPont
™
Flashing Systems products perform best when installed at temperatures above 25°F (–4°C).
Avoid placing DuPont
™
Tyvek
®
Wrap Caps where flashing will be installed; however, DuPont
™
Tyvek
®
Wrap Caps can be
applied over the flashing.
Where buildings could be exposed to extreme weather conditions (ie. sustained wind-driven rain above 50mph), install a
high pressure skirt to help prevent water intrusion at the sill.
Priming is generally not required for adhering DuPont
™
Flashing Systems products to most common building materials.
However, adverse weather conditions or cold temperatures may require use of a primer to promote adhesion. Additionally,
concrete,masonry,andber-facedexteriorgypsumboardrequiretheuseofapprovedprimers.Forprimer
recommendations, see page 2.
For additional guidelines and suggested sealants, please call 1-800-44-Tyvek (800-448-9835), visit our website at
www.Construction.Tyvek.com, or consult your local DuPont
™
Tyvek
®