Owner manual

50
TABLE 15: RIELLO 40F CHIMNEY VENT PRELIMINARY BURNER SETTINGS
Boiler Model Head Type
Inser-
tion
Depth
Firing
Rate
[GPH]
Com-
bustion
Liner
Nozzle
Mfr.
Nozzle
Type
Pump
Pres-
sure
[PSI]
Head
Setting
Air
Setting
Rated
AFUE
Efî‚¿ciency
[%]
4075
Reverse 2.75" 0.75
Oval Delavan
0.65x60W 150 1 3.6 86.0
4095
Standard 1.75" 0.95
Oval Delavan
0.75x90B 175 3 5.3 85.0
4110
Standard 1.75" 1.10
Oval Delavan
1.00x90B 125 1 3.1 84.0
5100
Standard 2.75" 1.00
None Delavan
0.75x60B 175 1 2.4 86.5
5115
Standard 1.75" 1.15
None Delavan
1.00x80B 130 2 2.8 85.0
5135
Standard 1.75" 1.35
None Delavan
1.20x80B 125 3 3.4 84.0
6130
Standard 2.75" 1.30
V6 Delavan
1.00x45B 175 2 3.6 86.5
6145
Standard 1.75" 1.45
V6 Delavan
1.25x70B 135 4 4.0 85.0
6165
Standard 1.75" 1.65
V6 Delavan
1.25x80B 175 2 2.8 84.0
7165
Standard 2.75" 1.65
V7 Delavan
1.35x60B 150 4 8.0 86.0
7180
Standard 1.75" 1.80
V7 Delavan
1.35x70B 175 2 3.4 85.0
7190
Standard 1.75" 1.90
V7 Delavan
1.50x70B 160 3 3.2 84.0
Timings
Pre-purge 12 seconds
17 - OIL BURNER, NOZZLE, & AIR SETTINGS
Table 15 - Riello 40F Chimney Vent Preliminary Burner Settings
Burner settings provided are for initial startup only. Final adjustments must be made using combustion test
instruments.
Boiler
Model
Riello
Oil
Burner
Model
ECR Oil
Burner
Part
Number
4075 40F3
240007502
4095 40F3
240009399
4110 40F5
240009400
5100 40F5
240007503
5115 40F5
240009401
5135 40F5
240009402
Boiler
Model
Riello
Oil
Burner
Model
ECR Oil
Burner
Part
Number
6130 40F5
240007504
6145 40F5
240009403
6165 40F10
240009404
7165 40F5
240007505
7180 40F10
240009405
7190 40F10
240009406