Specifications

Installation & Operation Manual for Flexible Batch Broiler
Australian Units
30
VI. WIRING SCHEMATIC
Sensor Rear IR Burner
IR Blower
Motor
Ignitor Front IR Burner
Ignitor Rear IR Burner
Relay
IR Blower
ON/OFF Switch
Sensor Front IR Burner
Capacitor
4uF
Conveyor Motor
Sensor
Lower Burner
Ignitor Lower Burner
1 2
1 2
2 1
1 2
1 2
1
1
1
1
1
1
3 2 1
Ignition
Xfmr.
J 6
J 5
J 4
J 3
BLK 11
WHT 11BLU 11
BRN 11
BRN 12
BRN 13
BRN 14
BLU 11
BLU 15
BLK
BLK
BLU 15
BLU 13
BRN 13
BLK
BLK
GRN/YEL
BRN 12
BLU 12
BRN 15
RED 15
RED 15
BLU 14
BLK
BLK
BLK
BRN
ORN
BLK
BRN
ORN
BLU
BLU
BLU
BLU
BLU 7
ORN 7
ORN 6
GRN 3
GRN 8
GRN 2
GRN 7
GRN 9
GRN 1
ORN 4
BLK 6
BLK 5
BLU 7
BRN 8
RED 5
YEL 1
ORN 4
BLU 6
ORN 6
ORN 8
YEL 1
RED 2
RED 3
RED 3
WHT 8
RED 4
GRN 7
GRN 2
GRN 1
GRN 9
WHT 8
BLU 4
BLU 4
GRN 8
GRN 3
J1 & J 2
View
BLU 6
IEC320 Cord
Inlet
24V
Controller
Xfmr
PRIMARY
SECONDARY
PRIMARY
SECONDARY
24V
Relay
Conveyor Motor
BLK 11
WHT 11
BLU 11BRN 11
ON/OFF Switch Connections
(Note: Indicator light Brn11 to Blu11)
ORN 8
BRN 8
2 1
2 1
BLK 14
+
Gas Valve IR
Burners
BLU 4
GRN 8
Gas Valve
Lower Burner
ORN 7
GRN 8
BLU 4
WHT 8
RED 4
GRN 4
S1
V2
GND
V1
TH
FC-
FC+
Ignition Control Module
Rear IR Burner (24-5-3)
S1
V2
GND
V1
TH
FC-
FC+
Ignition Control Module
Front IR Burner (24-5-3)
S1
V2
GND
V1
TH
FC-
FC+
Ignition Control Module
Lower Burner (7-5-3)
Thermocouple
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
2 1
T1
L1
+
Solidstate
Relay
T1
L1
+
Solidstate
Relay
3 2 1
J 1
J 2
Controller PC Board
Load Light
Note: Warranty is voided when water
sensitive stickers have changed color to red.
Pressure
Switch
SPST Relay:
24V~ Coil
ELECTRICAL SCHEMATIC FLEXIBLE BATCH BROILER
DUKE MFG, AUS w/ IR Air Pressure Switch, P.N. 175186_b
GRN 5
RED 5
RED 2
BLK 5
RED 5
BLK 5
3
5
1
1
4
2
3