Specifications
Installation & Operation Manual for Flexible Batch Broiler
Australian Units
26
SYMPTOM CAUSE REMEDY
Control display is reading “gAS
bot”
Broiler not receiving gas supply.
Cycle broiler off and back on. If this error
persists, proceed with the next steps.
Ensure that gas valve(s) in line with the
broiler are in the ON position.
Lower burner not lighting properly.
(Observe bottom burner through slits in
lower grease tray)
If broiler is hot, attempt to clean burner in
place with broiler cleaning tool.
If broiler is cold or allowed to cool down,
remove lower burner by removing access
panels, clean, and reinstall. Remove lower
ame sensor and clean with a soft cloth &
isopropyl alcohol.
Control display is reading “gAS
SEnt”
Infrared burners not lighting properly.
(Observe Infrared through discharge end
of broiler. Note: Burners should remain lit
in idle mode)
Remove upper control compartment panel
and clean 2 upper ame sensors with a soft
cloth & isopropyl alcohol.
Clean ame sensor tube with ame sensing
tube cleaning brush.
Control display is reading “gAS
SEnb”
Lower burner not lighting properly.
(Observe bottom burner through slits in
lower grease tray)
If broiler is hot, attempt to clean burner in
place with broiler cleaning tool.
If broiler is cold or allowed to cool down,
remove lower burner by removing access
panels, clean, and reinstall. Remove lower
ame sensor and clean with a soft cloth &
isopropyl alcohol.