Specifications
23
Installation & Operation Manual for Flexible Batch Broiler
Australian Units
C-4. Monthly Cleaning
DO NOT
LOAD
IF LIGHT ON
1
2
Remove top panel by
lifting up and out.
Locate the two ame sensors
for the Infrared burners.
With the broiler cool, remove
sensor by pulling on the black
covering near the ceramic.
Do not pull on the wire
to remove.
Clean the tip of the sensor up to the rst
ceramic with alcohol pad. Replace the
sensor. Take care to insert the sensor
all the way into the tube so the metal
retaining clip is no longer exposed.
With the broiler cool, remove the
rear panel of the broiler and remove
the sensor for the lower burner.
Follow the same procedures as
those for the top sensors.
After the sensor is removed take the T-handled
cleaning rod and carefully run the brush through the
Flame Sensor Tube. Push and pull the brush through
each tube a few times to make sure it is clean.