20
C-3. Weekly Cleaning
With outer front panel
removed, lift up the
combustion chamber panel.
Swing the right side of
the panel out as shown.
Clean and set aside.
2
1
Remove discharge panel and
scraper as was performed for
daily cleaning.
Remove burner shield.
2
1
Lift rear of burner out of saddle
and continue to hold it.
Orice
Hood
Pull burner off of orice and through broiler
wall. Remove from chamber. Clean, empty
any remaining water from the burner and
replace.
Thoroughly dry out all burner ports!
Lift ame arrestor up to
disengage tabs from slots. Tabs
are located under the front of the
arrestor.
Pull ame arrestor out.
Clean and reinstall.
TAB ON THE BOTTOM OF THE FLAME
ARRESTOR DROPS INTO SLOT