Specifications

Installation & Operation Manual for Flexible Batch Broiler
Australian Units
20
C-3. Weekly Cleaning
With outer front panel
removed, lift up the
combustion chamber panel.
Swing the right side of
the panel out as shown.
Clean and set aside.
2
1
Remove discharge panel and
scraper as was performed for
daily cleaning.
Remove burner shield.
2
1
Lift rear of burner out of saddle
and continue to hold it.
Orice
Hood
Pull burner off of orice and through broiler
wall. Remove from chamber. Clean, empty
any remaining water from the burner and
replace.
Thoroughly dry out all burner ports!
Lift ame arrestor up to
disengage tabs from slots. Tabs
are located under the front of the
arrestor.
Pull ame arrestor out.
Clean and reinstall.
TAB ON THE BOTTOM OF THE FLAME
ARRESTOR DROPS INTO SLOT