Service manual
Service Manual for Flexible Batch Broiler Units
8
PHU Pan Shelf
The PHU Pan Shelf is located on the discharge side of
the broiler and holds the unused holding pans.
1. Lift the pan shelf up and remove.
2. To install the pan shelf, slide the keyholes over
the two screws and slide pan shelf down.
PHU
Pan
Shelf
Discharge
Hood
PHU Pan Shelf and Discharge Hood
Discharge Hood
The Discharge Hood is located on the discharge side
of the broiler under the PHU Pan Shelf.
1. Remove the PHU Pan Shelf.
2. Remove the Discharge Hood by lifting out.
3. Install Discharge Hood by lowering into the side
grooves.
4. Reinstall the PHU Pan Shelf.
Discharge Chute
The Discharge Chute is located under the Discharge
Hood and guides the patties from the conveyor into
the Discharge Pan.
1. Remove PHU Pan Shelf.
2. Remove the Discharge Hood.
3. Remove Discharge Chute by lifting off of the two
side pins.
4. Reverse procedure to install Discharge Chute, being
sure to rest the hooks onto the pins on both sides.
Discharge
Chute Hook
Pin
Pin
Discharge Chute