Service manual

7
Service Manual for Flexible Batch Broiler Units
COVERS AND PANELS
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
Caution: If the broiler has been operating,
broiler panels and components may be
hot. Use PROPER PROTECTION.
Upper Lift Off Panel
The Upper Lift Off Panel provides access to the Upper
Flame Sensors, Igniters and Blower Hose.
1. Remove Upper Lift Off Panel by lifting up
and removing from broiler.
2. Install Upper Lift Off Panel by lowering into
the side grooves.
Control Side
Access Panel
Upper Lift Off Panel
REMOVAL AND REPLACEMENT OF COMPONENTS
Lower Control Side Service Panel
The Lower Control Side Service Panel provides
access to the Combo Gas Valves, Ignition Modules,
Transformers, Blower Motor, Conveyor Motor
Capacitor, and electrical connections to the Control
Board.
1. Remove the six screws securing the Lower
Control Side Service Panel.
2. Remove the panel from the broiler.
3. Reverse procedure to install the Lower
Control Side Service Panel.
Control Side
Service Panel
Screws
Lower Control Side Service Panel