Service manual
Service Manual for Flexible Batch Broiler Units
6
SPECIFICATIONS
NATURAL GAS PROPANE
MANIFOLD PRESS. TOP BURNERS 3.75″ WC 0.93 kPa 8″ WC 2.0 kPa
MANIFOLD PRESS. BOT. BURNER 3.75″ WC 0.93 kPa 8″ WC 2.0 kPa
ALTITUDE (MAXIMUM) 2000 FT 607 m 2000 FT 607 m
GAS PIPE CONNECTION 3/4" F-NPT 3/4" F-NPT
INLET PRESSURE RANGE 7"–12" W.C. 10"–12" W.C.
TOTAL ENERGY RATE 87,000 – 111,000 25.5 –32.5 79,000 –105,000 23.2 –30.7
BTU/HR kW BTU/HR kW
BURNER ORIFICE SIZE BURNER ORIFICE SIZE
FRONT INFRARED BURNER #40 2.49mm #52 1.61mm
BACK INFRARED BURNER #36 2.70mm #51 1.70mm
LOWER BURNER #31 2.05mm #49 1.85mm
ELECTRICAL
MODEL NUMBER VOLTAGE AMPS CYCLE PLUG
*FBB-NO-120 120 2 60 NEMA 5-15P
*FBB-NC-120 120 2 60 NEMA 5-15P
*FBB-PO-120 120 2 60 NEMA 5-15P
*FBB-PC-120 120 2 60 NEMA 5-15P
SHIPPING WEIGHT lbs Kg
BATCH BROILER (STANDARD) 482 219
SHIPPING DIMENSIONS Standard Metric (cm)
L X W X H 47″ X 34″ X 68″ 119.4 X 86.4 X 172.7
* Model Number Information:
• FBB-NO-120: Natural Gas No Catalyst
• FBB-NC-120: Natural Gas with Catalyst
• FBB-PO-120: Propane Gas No Catalyst
• FBB-PC-120: Propane Gas with Catalyst
WARNING
THIS BROILER IS DESIGNED TO
OPERATE WITH INCOMING NATURAL
GAS PRESSURES BETWEEN
7" AND 12" WATER COLUMN (WC).
SERVICE PRESSURES ABOVE
12" WC OR LESS THAN 2 PSI, WILL
REQUIRE DUKE’S HIGH SUPPLY
NATURAL GAS KIT (P/N 175689). THE
KIT INCLUDES COMPONENTS TO ADD
AN EXTERNAL REGULATOR TO THE
BROILER. THE REGULATOR SHOULD
BE ADJUSTED AFTER INSTALLATION
TO 7" WC PER THE ENCLOSED
INSTRUCTIONS. FOR INCOMING
PRESSURE LESS THAN
7" WC CONTACT GAS SUPPLIER.
TOOLS
Standard
• Standard set of hand tools.
• VOM with AC current tester (Any quality VOM
with a sensitivity of at least 20,000 ohms per volt
can be used).
• Manometer
• Pyrometer
• Gas Leakage Tester or method to test for gas leaks
• Conveyor Link Removal Pliers
• Duke Testing Harness