Service manual
Service Manual for Flexible Batch Broiler Units
28
UPPER IR BURNER AIR SUPPLY
The adjustments for the Upper IR Burner air supply
are accessible by removing the Upper Lift Off Panel.
There are two air adjustment screws located on each
side of the blower hose.
NOTE: The air adjustment is factory set and must
not be changed unless authorized to do so by Duke
Manufacturing.
1. Remove the Upper Lift Off Panel.
2. If found loose, reset to exposed thread measurement
to the setting indicated on the broiler.
Air Adjustment Screws
IR Burner Air Adjustment Screws
LOWER BURNER AIR SUPPLY
The adjustment for the lower burner air supply is factory
set and must not be changed. A properly adjusted natural
gas burner has a blue ame around the burner bend with
no yellow tips on the ame. A propane gas burner may
have a small amount of yellow tips on the ames. The
Air Shutter opening on factory J Burners is preset and
welded to 3/8" open. If replacing the J Burner, verify
this opening before installing it.