Replacing Conveyor Links
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Turn off and unplug the broiler.
2. Remove the front operator parts and panels. Refer to
the COVERS and PANELS section of the manual.
3. Spread the damaged link with Link Tool at both
ends.
4. Remove the damaged link.
5. Install the new link.
6. Use pliers to close both ends of the link.
7. Check for proper operation. It may be necessary to
add or remove shims behind or under the bushing
blocks to ensure proper tension.
NOTE: Never remove a link without replacing a link.