Service manual

Service Manual for Flexible Batch Broiler Units
24
Main
Power
Switch
Control
Board
Main Power Switch
Blower Motor
The Blower Motor is located on the Control Board
side of the broiler and is accessed by removal of the
Upper Lift Off and Lower Control Side Service Panels.
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Remove the Upper Lift Off Panel. Refer to the
COVERS and PANELS section of the manual.
2. Remove the Lower Control Side Service Panel.
Refer to the COVERS and PANELS section of the
manual.
3. Disconnect wires from the Blower Motor.
4. Loosen Blower Hose clamp and disconnect the
hose from top of Blower Motor.
5. Remove three screws attaching Blower Motor to
frame.
6. Reverse procedure to install a new Blower Motor.
Replace gasket when installing new Blower Motor.
Blower Motor
Assembly
Screws
Hose
Clamp
Blower Motor