Service manual
23
Service Manual for Flexible Batch Broiler Units
3. Remove screws securing Transformer to frame.
4. Remove Transformer.
5. Reverse procedure to install a Transformer.
Control Board
Step-Down
Transformer
Ignition Module
Step-Down
Transformer
Step-Down Transformers
Solid-State Relays
Two Solid-State Relays are accessible by removing the
Lower Control Side Service Panel. The left Solid-State
Relay controls the Conveyor Drive Motor. The right
Solid-State Relay controls the Blower Motor.
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Remove the Lower Control Side Service Panel.
Refer to the COVERS and PANELS section of the
manual.
2. Disconnect wires from the Solid-State Relay to be
removed.
3. Remove screws securing Solid-State Relay to
frame.
4. Remove Solid-State Relay.
5. Reverse procedure to install a Solid-State Relay.
IR Blower
Motor Relay
Conveyor Drive
Motor Relay
Solid-State Relays
Main Power Switch
The Main Power Switch is located on the front of the
broiler below the Control Board.
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Remove Lower Control Side Service Panel. Refer to
the COVERS and PANELS section of the manual.
2. Disconnect switch wires.
3. Pinch the spring tabs on the top and bottom of the
switch and slide out through front of panel.
4. Reverse procedure to install a new Main Power
Switch.