Service manual
21
Service Manual for Flexible Batch Broiler Units
Upper
Combo Gas Valve
Lower
Combo Gas Valve
Burner
Gas Lines
Input
Gas Lines
Combo Gas Valves
Cook Chamber Temperature Probe
The Cook Chamber Temperature Probe connects to
the bottom of the Control Board and is located on the
back of the broiler.
WARNING
DISCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDURES.
1. Remove the Lower Control Side Service Panel.
Refer to the COVERS and PANELS section of the
manual.
2. Remove the Rear Panel. Refer to the COVERS
and PANELS section of the manual.
3. Disconnect the Cook Chamber Temperature Probe
connector at the bottom of the Control Board.
4. Remove the Cook Chamber Temperature Probe
from the bracket by pushing down gently on the
bracket.
5. Pinch the two grommets in the electrical
compartment to remove them.
6. Slide the Cook Chamber Temperature Probe out
of the broiler.
7. Reverse procedure to install a Cook Chamber
Temperature Probe, ensuring the two grommets
are reinstalled.
8. Ensure the Cook Chamber Temperature Probe is
seated correctly on the its mounting bracket. The
notch on the sheath must be locked on the bracket.
Cook Chamber
Temperature
Probe
Connection
Cook Chamber Temperature Probe Connection