Service manual
Service Manual for Flexible Batch Broiler Units
16
1. Remove Upper Lift Off Panel. Refer to the
COVERS and PANELS section of the manual.
2. Loosen Blower Hose clamp at output of Blower
Motor.
3. Loosen hose clamp at center of air supply to upper
burners.
4. Remove Blower Hose.
5. Reverse procedure to install Blower Hose.
Infrared
Air
Tube
Air Tube Clamp
Blower Hose
Upper Flame Sensor Assemblies
The Upper Flame Sensor Assemblies are accessible by
removing the Upper Lift Off Panel. Each upper burner
has a corresponding Flame Sensor Assembly.
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Remove the Control Side Access Panel. Refer to
the COVERS and PANELS section of the manual.
2. Remove Lower Control Side Service Panel. Refer to
the COVERS and PANELS section of the manual.
3. Disengage Upper Flame Sensor from guide and
bracket, and pull out of guide and bracket.
Mounting
Guide
Porcelain
Insulator
Flame
Sensors
Flame Sensor
Wire
Upper Flame Sensor
4. Disconnect Upper Flame Sensor wire from Ignition
Module and remove Upper Flame Sensor Assembly.
5. Pinch the tabs on the wire grommets to remove
them.
6. Feed wire through shelf to completely remove the
Flame Sensor Assembly.
7. Reverse procedure to install a new Upper Flame
Sensor Assembly.
Upper Igniter Assemblies
The Upper Igniter Assemblies are accessible by
removing the Upper Lift Off Panel. Each upper burner
has a corresponding Igniter Assembly
WARNING
DISCONNECT THE ELECTRICAL POWER
TO THE BROILER AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Remove the Upper Lift Off Panel. Refer to the
COVERS and PANELS section of the manual.
2. Remove Lower Control Side Service Panel. Refer to
the COVERS and PANELS section of the manual.
3. Remove two screws securing igniter cover.