Top Service Panel
The perforated Top Service Panel provides access to
the two Infrared Burners
1. Remove the four screws securing the perforated
Top Service Panel.
2. Remove the perforated Top Service Panel from the
broiler.
3. Reverse procedure to install the perforated Top
Service Panel.
Top
Service
Panel
Flue
Restrictor
Top Service Panel
Removing the Front Panel
1. Slide the Loader out of the Loader Tray.
2. Unlatch the Loader Tray and slide it out of the
Loader Tray Mounting Brackets.
3. Pull the Main Grease Pan out of the front of the
broiler.
4. Pull the V Grease Pan out of the front of the broiler.
5. Lift the Front Panel up and away from the broiler.
6. Reverse these steps to reinstall these parts.
Front Access Panel
Front Panel
Removing the Rear Panel
1. Lift the Rear Panel up and away from the broiler.
2. Reverse to reinstall the Rear Panel.
Rear Access Panel