Welding System User Manual
Section 7 – Troubleshooting
Page  47
Dukane Manual Part No. 403-577-01
No Ultrasonic Output
Probe
Make sure that the hand probe cable is connected to the 
generator  connector  (HAND  PROBE)  and  secured  to  
the  rear  panel. Also,  make  sure  the  hand  probe  stack  is 
properly assembled.
System Power Output Level
Overload
When  an  overload  occurs,  it  will  automatically  reset 
when the next ultrasound activation  signal begins. If the 
condition persists:
Turn the generator OFF and:
1.  Check the system. Change the hand probe to one that 
is known to be good.
2.  Turn the generator ON, and see if the fault condition 
has been corrected. 
Overtemperature
When the  system  overheats,  and the generator’s  internal 
temperature  exceeds  85° C  (185°  F)  an  overtemperature 
fault condition will trip.
When  the  system  cools,  the  system  automatically  resets 
the overtemperature fault.
Generator Fault Does Not Reset
When a  system fault condition does  not automatically 
reset, the generator needs servicing.
System Power Diagnostic
Procedures
The only fault  indications available with these probe 
systems are the ones shown on the LCD display. 
NOTE
The  LCD  screen  displays  a  vari-
ety  of  pop-up  status  changes  as 
they  occur.  Check  Tables  7-I  and 
7-II - Pop-up Fault Status Screens 
- Pages 49- 50. 
NOTE
When  Latching  Faults is enabled, 
ENTER  must  be  pressed  to  clear 
a fault. 