Welding System User Manual
Page  35
Section 6 – Probes and Probe Stacks
Dukane Manual Part No. 403-577-01
Figure 6-1 Typical Hand Held Probes
 U/S Cable
 Typical Horn Less Tip
 Models
 Pistol-style Grip
 Hanger
 Trigger
 Typical Horn Less Tip
 U/S Cable
 Trigger Actuator
 Hand Grip
 Compressed Air Fitting
 Strain Relief
 Strain Relief
Rear View
Rear View
 Compressed Air Fitting
41PG40 & 41PG40S
 Models
41HP40 & 41HP40S
 Hanger
Ultrasonic Probe
Overview
The  two  types  of  probes  used  with  the  iQ  Hand  Held 
Systems are shown in Figure 6-1 below.
Operating Notes
Compressed Air  Fitting -  In  continuous  duty 
operation, it  is important to keep  the probe cool  with 
compressed air. Use the air tting to connect the air source 
to the probe.
See Section 7, Specications for more detail.
CAUTION
The  ultrasonic  cable  car-
ries high electrical current 
when in operation. Do not 
nick  or  cut  this  cable.  If 
cut, there would be a high 
potential for electric shock! 
NOTE
Compressed air supply: Make sure 
the air is clean, oil-free, and dry.