Welding System User Manual
Page  31
Section 5 - Process Control Settings
Dukane Manual Part No. 403-577-01
Setup Maintenance Continued
Saving the Current Setup
Try using your navigation skills on this example:
1.  Follow  instructions  on  Page  24  to  set  the  mode  to 
Weld by Time. Set the time to 1.520 seconds.
  See Figure 5-23.
2.  Press SETUP and then press the   
+
   key until you 
get an Empty Setup Maintenance screen.
  See Figure 5-24.
3.  Use  the  right  arrow  key  to  select  Store,  and  then 
press  ENTER. You  will  be  returned  to  the  Operate 
screen. 
4.  Conrm that your setup has been stored in memory 
by  going  back  to  SETUP.  Your  new  setup  should 
appear, just as it does in Figure 5-25.
Selecting a Setup
To select a setup previously stored:
1.  Press SETUP.
2.  With Load highlighted, use the             keys to select 
the number of the setup you want.
3.  Press ENTER.
4.  The  Operate  screen  will  display  this  selection  as  a 
number in the lower left hand corner.
Deleting a Setup
To delete a setup previously stored:
1.  Press SETUP.
2.  With Delete highlighted, use the              keys to select 
the number of the setup you want.
3.  Press ENTER, and a pop-up  screen will ask you to 
conrm your selection. Make your choice, and press 
ENTER.
4.  Check that the setup is deleted. Press SETUP, and the 
Setup Maintenance screen will show EMPTY for the 
setup you just deleted.
Figure 5-23 Save Current Setup 
Figure 5-24 Store in Setup Maintenance 
Figure 5-25 New Setup Stored
Setup Maintenance
  Load 
Store
Setup # 1
T: 1.520 S A: 100%
Mode: Manual
E: 0 J H: 0.0 S
Delete
Weld by Time
Press Enter To Accept
Press Cancel To Abort
Weld Time
1.520 S
Setup Maintenance
  Load 
Store
Setup # 1
EMPTY
Delete
+ -
+ -