Welding System User Manual
Page  30                   
iQ  Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
Setup Maintenance
Introduction
The screens  available in Setup Maintenance  allow the 
operator to Load, Store, or Delete generator weld setups.
As many as eight (8) setups can be loaded and stored for 
your convenience. 
Navigating
1.  When the SETUP key is pressed for the rst time, the 
display looks like Figure 5-18. This screen indicates 
that Setup #1 is Empty. Because there is not yet any 
data  available,  this  setup  has  nothing  in  it,  and  is 
empty. You will see that Load is highlighted.
  Press ENTER.
2.  Load - (Load means to put data into the generator’s 
memory, or to program a setup.)
  A pop-up screen asks if defaults should be loaded for 
Setup #1. See Figure 5-18A.
  Select NO, and the display will change to an Operate 
screen.
  Select YES, and Manual Weld shows at the top of 
the Operate screen that will display next. The setup 
number appears in the lower left corner of the screen. 
Refer to Figure 4-4.
3.  After  selecting YES, press  SETUP,  and  the  display 
will look like Figure 5-19.
4.  Store - (Store means to save the setup data.)
  Tap the right arrow key once to highlight Store.
  See Figure 5-20.
5.  Press ENTER, and  a pop-up screen as shown in 
Figure 5-21 appears.
6.  Select  YES  if  you  want  to  overwrite  (replace) 
whatever is in the setup, and select NO if you do not 
want to change anything for that setup.
  Press the ENTER key to save your selection.
7.  Delete -To delete the setup, select Delete as shown 
in Figure 5-22, and press the ENTER key. A pop-up 
screen appears to ask you to conrm your choice.
  Select YES or NO, and press ENTER again.
Setup Maintenance
  Load 
Store
Setup # 1
EMPTY
Delete
Figure 5-18 Setup Maintenance - 1 
Setup Maintenance
  Load 
Store
Setup # 1
T: 0.000 S A: 100%
Mode: Manual
E: 0 J H: 0.0 S
Delete
Figure 5-19 Setup Maintenance - 2
Setup Maintenance
  Load 
Store
Setup # 1
T: 0.000 S A: 100%
Mode: Manual
E: 0 J H: 0.0 S
Delete
Figure 5-20 Setup Maintenance - 3 
Figure 5-21 Pop-up Overwrite Setup?
Setup Maintenance
  Delete
Store
Setup # 1
T: 0.000 S A: 100%
Mode: Manual
E: 0 J H: 0.0 S
Load
Figure 5-22 Setup Maintenance - 4 
NO
Overwrite
Setup #1?
YES
NO
Setup #1 Empty
 Load Defaults?
 YES
Figure 5-18A Pop-up Load Defaults? 
Continued