Welding System User Manual
Page  28                   
iQ  Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
3.  Advanced Settings    Continued 
  After Advanced Settings is selected, a warning screen 
is displayed as shown in Figure 5-13.
  Adjusting these settings may affect the operation of 
your unit. Before you change a setting, please check 
with Dukane personnel for their recommendations.
  The warning screen is shown for a few seconds, then, 
the Advanced Settings screen appears.
  See Figure 5-14.
  Adjustments can be made to: Free Run Frequency; 
Ramp Up Time; Frequency Lock and Hold; and, Trig-
ger By Power, but note that Trigger by Power is only 
available when the weld mode is time or energy. 
Free Run Frequency
  Free  run  is  the  frequency  at  which  the  generator 
drives the  ultrasound ouput  pulses  until a  valid 
feedback signal is detected. Typically this value 
should be below the operating frequency of the 
probe.
    Follow  the  on screen  prompts  to  make  setting 
adjustments.
Ramp Up Time
This  parameter  increases the  amplitude linearly  in 
the programmed time period at the start of the weld 
from zero to the programmed amplitude level. This 
brings the probe up to operating amplitude smoothly 
preventing shock stress.
  Follow  the  on screen  prompts  to  make  setting 
adjustments.
Lock and Hold
For  an  explanation  of  Frequency  Lock  and  Hold, 
please refer to Application Note 505 found on our 
website at:
http://www.dukane.com/us/DL_ApplData.asp
    Follow  the  on screen  prompts  to  make  setting 
adjustments.
            Continued
NOTE
Trigger by Power is only avail-
able  when  the  weld  mode  is 
either Time or Energy.
Figure 5-13 Warning Screen 
 Warning
Modified settings
may affect operation 
of this unit! 
Figure 5-14 Advanced Settings Screen 
Advanced Settings
> Trigger By Power
ON OFF
Press Enter To Accept
Press Cancel To Abort
 Lock and Hold
  ON OFF
 Ramp Up Time
 Free Run Freq
 19900Hz
 150mS