Welding System User Manual
Page  26                   
iQ  Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
Hold
HOLD  is  used  more  often  with Time  or  Energy  modes, 
but it can be used with the Manual mode. It is a period of 
time that can be set to follow release of the probe’s trigger 
switch. 
During  HOLD  the  operator  typically  applies  pressure  to 
the part being welded. Next, the operator hears an audible 
alarm that serves as a reminder that HOLD has nished, 
and the probe can be lifted.
HOLD does not allow the operator to begin a new cycle 
until HOLD is nished.
To set a HOLD period:
1.  Select the weld mode (Manual, Time, Energy).
2.  Set the time and energy parameters as needed.
3.  Press  the  HOLD  key.  The  screen  will  appear  as  it 
does in Figure 5-9.
4.  Set the time with the 
+ -
 keys.
  (A maximum of 5.0 seconds.)
  Figure 5-9A shows a setting for 2.0 seconds.
5.  Press the ENTER key to conrm your selection.
Amplitude Adjustment
Amplitude  refers  to  the  movement of  the  horn  at  its 
workface. The higher the amplitude setting, the higher the 
power output level will be at a particular pressure level.
Amplitude  settings  are  given  as  a  percent  of  the  horn’s 
nominal amplitude in the range of 20% to 100%.
It  is  typical  to  leave  the  amplitude  setting  at  100%  for 
maximum power output.
To adjust amplitude:
1.  Press  the  AMP  key.  The  screen  will appear  as  in 
Figure 5-10.
2.  Set the amplitude level using the   keys and the  
+ -
 keys.
3.  Press ENTER to conrm your amplitude setting.
Hold Time
 OFF S 
Figure 5-9 HOLDTime - 1 
Amplitude
 100 % 
Figure 5-10 Amplitude 
Hold Time
 2.0 S 
Figure 5-9A HOLDTime - 2 
NOTE
The generator’s end of  HOLD signal 
will only be heard if the audible alarm 
is ON.
The Audible Alarm can be set ON or 
OFF.  See  Hardware  Settings  on  the 
next page.