Welding System User Manual
Page  25
Section 5 - Process Control Settings
Dukane Manual Part No. 403-577-01
Navigate to Energy Mode
1.  Follow the sequence shown in the gures to the right 
to navigate from Time mode to Energy mode.
  In Time mode (Figure 5-5), press the ENERGY key, 
and the screen as shown in Figure 5-6 appears.
2.  The phrase,  Enter  Changes Mode,  means  when the 
ENTER  key  is  pressed,  the  mode  will  change.  So 
press the ENTER key, and the Weld by Energy screen 
seen in Figure 5-6A appears.
3.  Use the              and the             keys to move the 
cursor and to set the digits for the energy you want. 
See Figure 5-7.
4.  Press the ENTER key to accept the energy that has 
been set. Press the CANCEL key if you decide not to 
set the energy.
5.  If  you set the energy level, a maximum weld time 
needs to be set also. Set a time that is reasonable for 
your application. [The factory default for this time is 
30 seconds (also the maximum).]
  The time can not be set below 0.001 second.
  Use the           and the           keys to move the cursor 
and to set the digits for the time you want.
  See Figure 5-8.
+ -
+ -
Weld by Time
Weld Time 0.500 S 
Weld Energy 00 J 
# 2 
Figure 5-5 Time Weld Mode 
ENERGY 
key
Weld by Time
Hit Enter To Accept
Hit Cancel To Abort 
Weld Time 
 0.500 S
ENTER key
Figure 5-6 Navigate to Energy Mode - 1
Figure 5-7 Energy Weld Mode - 1
Weld By Energy
Maximum Weld Time 
 1.000 S 
Figure 5-8 Energy Weld Mode - 2 
Set energy 
level.
Weld By Time
Enter Changes Mode 
Weld By Energy 
 OFF 
Weld By Energy
Press Enter To Accept
Press Cancel To Abort
Weld Energy
27 J
Weld By Energy
Press Enter To Accept
Press Cancel To Abort
Weld Energy
OFF J
Figure 5-6A Navigate to Energy Mode - 2
Weld by Time
Hit Enter To Accept
Hit Cancel To Abort 
Weld Time 
 0.500 S
ENTER key