Welding System User Manual
Page  20                   
iQ  Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
LCD Display Overview
There are two basic kinds of screen displays:
Operate screens, and In Cycle screens.
Figure 4-5 Example of an In Cycle Screen 
 IN CYCLE
Frequency: 40087 Hz
Power: 25 W
# 2
Status Indication
Stack Frequency
Power Draw
Power Bar Graph %
Figure 4-4 Example of an Operate Screen 
Weld Mode - 
Manual, Time, or 
Energy
Manual Weld
Weld Time 0.500 S
Weld Energy 18 J
# 2 
*
Data from 
last weld 
cycle.
Setup 
number.
Asterisk indicates setup 
is modied but not 
stored in memory.
An  Operate  screen tells  the  operator 
what happened in the last weld cycle.
An In Cycle screen activates when the probe activation 
switch (trigger) is pressed. 