Welding System User Manual
Page  18                 
iQ  Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-577-01
CAUTION
Make sure the stack is prop-
erly  assembled  before  it  is 
connected to the system. The 
horn  should  never  come  in 
direct contact with a metal x-
ture or anvil when ultrasound 
is activated. 
Control Keys
AMP
Set the ultrasound amplitude output level in the range of 
20 to 100%.
Typically amplitude is set to 100%.
TIME
Use this  key to select  time as the  primary  method of 
welding. Set the weld time (seconds). 
ENERGY
Use  this  key  to  select  energy  as  the  primary  method  of 
welding. Set the weld energy (joules). 
HOLD
Hold  is  a  time  period  beginning  after  the  weld  portion 
of the cycle is complete. The operator holds the probe in 
place applying pressure to the weld, and an audible alarm 
indicates that the Hold time is nished. Hold can be set to 
a maximum of 5.0 seconds.
ENTER
Press the ENTER key to select a menu item, and move to 
the next level of the menu. Think of it as a “forward” key. 
When  pressed,  it  also  conrms  and stores  a  selection  in 
memory. It is also used to reset a latched condition. 
Arrow Keys
Press the right and left arrow keys to move the cursor to 
the right or left. 
+ and - Keys
Press  these  keys  to  increase  or  decrease  the  value  of  a 
selected digit. 
CANCEL
Press CANCEL to return to the previous screen. Think of 
it as a “back” key. Press this key when you do not want to 
store the selection in memory. 
System LCD Display
This high resolution, multi-line display provides a clear 
graphic interface to the operate and in-cycle screens 
needed to monitor and program the system.
Power Bar Graph
The Power Bar Graph appears at the bottom of the 
LCD display. It contains 20 segments that represent the 
generator’s range of power from 0% at the far left of 
the bar graph to 100% of power at the far right. Each 
segment equals 5% of the total.
In the example below, 40% of the available power is used 
during the weld cycle. The display shows an In Cycle 
screen (while U/S is active).
 IN CYCLE
Frequency: 40087 Hz
Power: 225 W
# 2
40% of 
power used 
In Cycle 
screen
Operate 
screen
In the example below, 40% of the generator power was 
the maximum (peak) power delivered in the previous 
weld. The display shows an Operate screen (while U/S is 
inactive).
Weld by Time
Weld Time 1.500 S
Weld Energy 24 J
# 1 
40% of power delivered in previous weld  
Figure 4-1A Power Bar Graph - In Cycle
Figure 4-1B Power Bar Graph - Operate
Continued