Welding System User Manual
Page  17
Section 4 – Controls and Connections
Dukane Manual Part No. 403-577-01
Figure 4-1 Front Panel
Front Panel Overview
This section gives an overview of the front panel functions: 
powering the generator on/off; monitoring the process with 
the display; and, programming with the control keys.
Control Keys
The  control keys  shown  in  Figure 4-1  and  described 
below, are used to display information, and to program 
the generator.
INFO
Press this key to get system information or to modify the 
hardware settings.
System Information  -  Identies  the current 
version of system software.
Hardware Settings - Select features that can be 
turned on or off including the Audible Alarm or Fault 
Latching options.
SETUP
Use the SETUP key to Load, Store, or Delete as many as 
eight setups.
Power 
Switch
Control Keys
LCD Display
Power Switch/Circuit Breaker
The power switch/circuit breaker has a rocker-style actua-
tor  switch  that  will  activate  or  deactivate  the AC power 
to the system. The power ON position is marked with the 
internationally recognized I symbol, the power OFF posi-
tion is marked with the 0 symbol. This power switch also 
integrates  an  appropriately  sized  over-current  protection 
circuit breaker function in the generator.
If an over-current condition trips the circuit breaker, it will 
automatically switch to the OFF position. If the overload 
current that caused the circuit breaker to trip is due to a 
transient  condition,  the  circuit  breaker  can be  reset  by 
switching the actuator back to the ON position. 
CAUTION
If  when  resetting  the  circuit 
breaker  afer  it  has  tripped,  it 
immediately trips again, there 
is  likely  an  internal  system 
malfunction, and the generator 
will need service. Do NOT re-
peatedly try to reset the circuit 
breaker. If it trips, this will only 
cause  more  damage  to  the 
generator. 
            Continued